Recherche
MENU Catalog Global Sites
BAMO
INTERNATIONAL
European manufacturer of sensors and instruments for liquids
You are in BAMO EU » Archives » Chlorine, Disinfection » CP2.1
General Catalog 193-05
CP2.1
CP2.1
Total chlorine sensor
CP2.1
Attention! You are currently viewing old documentation:

This section of our website concerns references that are no longer manufactured or marketed.
Please use with caution.
CP2.1

Water treatment, drinkable quality and sea-water
- Low incidence of pH changes
- Surfactants: partial tolerance
- Operating temperature 45 °C max.
- Operating pressure 0.5 bar max.

TECHNICAL FEATURES

Measuring parameter: Total chlorine (Free + combined chlorine)
Applications: Water treatment (drinkable quality water and sea water)
Surfactants: partial tolerance
Chlorination additives: Inorganic compounds, such as NaOCl - Ca(OCL)₂ - gaseous chlorine - chlorine by electrolysis
Output signal: 4 ... 20mA
Operating temperature: 1 to 45 °C
Automatic temperature compensation
Operating pressure: 0.5 bar max. (No vibrations, no pulsating flow)
Flow rate: About 30 l/h
pH operating range: pH 4 to pH 12 (low incidence of pH)
Interferences: Incidence of ClO₂ and O₃ on measuring signal
Zero adjustment Not necessary (from factory)
Slope calibration Only 1 point with BAMOPHAR 194 according to directive DPD-4

Measurement ranges

CP2.1.MA2     0.01 ...  2 mg/l
CP2.1.MA5     0.01 ...  5 mg/l  
CP2.1.MA10   0.01 ... 10 mg/l

General Catalog 193-05
26/03/2022 19:02
Total chlorine sensor
CP2.1
Technical & Commercial support's main contacts
Ask a QUOTATION online
BAMO Mesures SAS
22, Rue de la Voie des Bans
Parc d'activités de la Gare
95100 ARGENTEUIL France
Tel : +33 (0)1 30 25 83 21
Fax : +33 (0)1 34 10 16 05
Email : export@bamo.fr
Site : http://www.bamo.eu
Siret : 314 055 864 000 65
TVA Intra : FR 08 314 055 864
APE : 2651 B
Capital : 400 000 €
Designed and hosted by CARIMEDIA since 1998
© 1998-2024 All rights reserved - Disclaimer