• For water treatment • Low incidence of pH changes • Surfactants: partial tolerance • Temperature: 45 °C max. • Pressure: 0.5 bar max.
APPLICATIONS
Water treatment (for water equivalent to drinkable quality)
TECHNICAL FEATURES
Measured parameter: Hypobromous acid (HOBr) Disinfection additives: Hypobromous acid (HOBr); bromochloro-dimethylhydantoin (BCDMH) Measuring system: Closed cell with 3 electrodes and electrolyte Supply voltage: 12 ... 30 V DC (Load 500 to 900 Ω) Output signal: 4 ... 20 mA, screw connectors x2 (1mm²) Operating temperature: 5 to 45 °C; Automatic temperature compensation Operating pressure: 0.5 bar max. (No vibrations, no pulsating flow) Flow rate: About 30 l/h pH operating range: Between pH 6.5 and pH 9.5; Low incidence of pH changes Zero adjustment: Not necessary (from factory) Slope calibration: Only 1 point with BAMOPHAR 194 according to directive DPD - Free bromine: DPD-1 - BCDMH: DPD-4 Interferences: Incidence of Cl₂, ClO₂ and O₃ on measuring signal Materials: PVC, PEEK, AISI 316 Ti (1.4571) Dimensions: O.D. 25 mm, length 220 mm (4-20 mA)
General Catalog 193-09 18/04/2025 04:46
Bromine sensor BR1
BAMO Mesures SAS
22, Rue de la Voie des Bans Parc d'activités de la Gare
95100 ARGENTEUIL France