Mempro EX 2 C
Fill level monitoring in ATEX Ex area
For flammable liquids
No moving parts
Accurate and reliable measurement
Output signal 4-20 mA, 2 wires
Free from fluid viscosity or conductivity
Scales: up to 4000 mm
ATEX certification
PRINCIPLE
The MEMPRO Ex C measuring instrument operates in accordance with the Pitot static principles, i.e. the level signal is proportional to the hydrostatic pressure in a measuring tube plunged into the liquid. It is used for measuring fill-levels of flammable liquids.
The device is approved for use in danger zone 0 for flammable media assigned to explosion group IIC.
The MEMPRO Ex C fill-level transmitter is used as a passive 2-pole device in intrinsically safe circuits.
It converts the backpressure signal into a load independent current within a range of 4 to 20 mA.
APPLICATIONS
For measuring the fill level of tank (atmospheric pressure) with an Ex area requirement.
The device is suitable for flammable liquids and for use in ATEX Ex area (see the agreements herein after). The sensor (ceramic) is in contact with the vapours not directly with the fluid.
General Catalog 592-25 21/01/2021 11:00
Hydrostatic level transmitter MEMPRO Ex 2 C
BAMO Mesures SAS
22, Rue de la Voie des Bans Parc d'activités de la Gare
95100 ARGENTEUIL France