• Applications: Totalization; Low flow-rates • Versions: Or in Arnite, or in PVDF • Ranges: From 2 up to 940 l/h • High resolution frequency output • Fitting: BSP ¼''
APPLICATIONS
- With neutral or aggressive liquids - Clear liquids free of particles, non-crystallizing.
The flow must be homogeneous and piping always full of liquid. (FFG turbine type is not suitable for measuring gas flow)
DESCRIPTION
The FFG flow sensor allows measurements of low flow-rates for remote reading or totalization with appropriate monitors (See Codes and References on next page)
The dynamic pressure of the liquids makes rotate the turbine. The liquid passes through a calibrated nozzle, which increases its speed and that of the turbine. Magnets are integrated to the turbine and activate an Hall effect sensor inside the top cover. The electronic generates a pulsating signal, proportional to the speed of rotation of the turbine and therefore to the flow-rate.
Recommendations for assembly: The FFG works in any position, but it is recommended to mount it on a horizontal axis, with its upper body in a horizontal plane, to obtain reliable and precise measurements. Respect the straight pipe section of 150 mm upstream and 50 mm downstream in order to obtain a uniform flow. Installing an upstream filter prevents suspended particles from blocking the turbine (during commissioning, and, normal operation).
Associated electronics: - BAMOWIZ : Flow rate indicator and flow totalizer, digital and graphical display, relays and analogue outputs (Data-sheet 217-01) - BIF 6040: Flow indicator and totalizer with options for thresholds and analogue output (Data-sheet 282-01) - BCP 48: Counter and downcounter for dosage with 2 set points (Data-sheet 289-03) - BAMOTOP 281: Frequency converter for analogue output 0/4-20 mA or 0/5-10 V (Data-sheet 281-01)
General Catalog 784-01 20/01/2021 17:05
Turbine flow sensor FFG
BAMO Mesures SAS
22, Rue de la Voie des Bans Parc d'activités de la Gare