• Flow-rate sensor for domestic hot water, drinkable water, demineralised water • Measuring range from 0.9 to 150 l/min • Pipes from ND 8 to ND 25 mm • Output signal: or 4-20 mA or pulses • Drinkable water approvals: WRAS,ACS
APPLICATIONS
Flow measurement on domestic hot water, drinkable water or non-conductive liquids such as demineralised water or reverse osmosis water.
DESCRIPTION
This flowmeter, which has no moving mechanical parts, is not affected by a pollution. It is distinguished by a low pressure drop and a good accuracy.
The flow sensor is based on the principle of Karman vortex trail. The frequency of vortices generated by the obstacle located in the flow path, is proportional to the flow speed. Turbulences are detected by a piezoelectric paddle, operated by an integrated electronics.
General Catalog 777-01 04/04/2022 11:10
Flow sensor, Vortex type VORTEX
BAMO Mesures SAS
22, Rue de la Voie des Bans Parc d'activités de la Gare
95100 ARGENTEUIL France