Mounting in all positions Construction: cast iron or stainless steel For pipes from ND 40 up to ND 300 mm Scale amplification from 2 to 10 Accuracy: ± 2.5 % Options: High or/and Low flow switches
DESCRIPTION
The orifice plate flow indicators U6 are specifically designed for the measurement of high flow rates.They are suitable for pipes with a diameter equal or over 2". The direct reading is done on a variable area flow meter. For an optimal accuracy, the diaphragm characteristics are calculated against the process parameters (see further on).
Mounting: From factory, by construction, you can ask for a mounting position according to process.
TECHNICAL FEATURES
Measuring range:
1 to 1600 m3/h [Water at 20°C]
180 to 200 000 Nm3/h [normo m3/h of air]
Accuracy: ± 2.5% full scale Repeatability: ± 0.5% reading Scale amplification: from 2 to 10 - Linear scale Temperature limits:
0 ... 90 °C, sealing in Buna
0 ... 120°C, sealing in FPM
Pressure limit: 21 bar as a maximum
MATERIALS
Wetted parts:
Cast iron and brass (standard) Stainless steel 316 (on request) Diaphragm: Stainless steel 316
Flow indicator:
Borosilicate glass tube
Diver:
Stainless steel 316 SS (liquids)
Aluminium (gases)
Sealing:
O-rings in Buna N (as standard)
FPM on request
General Catalog 764-01 10/04/2018 08:45
ORIFICE PLATE FLOW INDICATOR U6 series
BAMO Mesures SAS
22, Rue de la Voie des Bans Parc d'activités de la Gare
95100 ARGENTEUIL France