Our 3-way ball valves are supplied in a standard operating mode accordingto anti-clockwise rotation of 90°
Mode L1:Distribution to 2 downstream circuits1 Inlet; 2 Outlets
Start at 0°Inlet: Channel N° 3Outlet: Channel N°1
End at 90°Inlet: Channel N° 3Outlet: Channel N° 2
Mode T1: Mixing2 Inlets; 1 OutletStart at 0°Inlet: Channel N° 2Outlet: Channel N°1End at 90°Inlet: Channel N° 3Outlet: Channel N° 1–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Mode T2: Distribution1 Inlet; 2 OutletsStart at 0°Inlet: Channel N° 2Outlet: Channel N°3End at 90°Inlet: Channel N° 2Outlet: Channel N° 1–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Mode T3: Distribution + Direct flowStart 0°: 1 Inlet; 2 OutletsEnd 90°: 1 Inlet; 1 OutletStart at 0°Inlet: Channel N° 2Outlets: Channel N° 1 & 3End at 90°Inlet: Channel N° 2Outlet: Channel N° 3