• Direct reading • Materials PVC, PPH • Magnetic pointer for level switches • For tanks and drums
APPLICATIONS
- Level of clear chemicals or wasted liquids in opaque tanks, drums or underground tanks. - Direct control of pumps, valves, alarm signals, with the use of level switches.
DESCRIPTION
A float at the bottom of a stem moves a pointer inside a transparent PVC tube, outside the tank. The reading is direct through the transparent tube.
• Model FS4 Standard The standard model is designed for tanks. For the float, the guiding tube has an O.D. of 63 mm. The mounting is on the top of the tank, with a loose flange ND 65.
• Model FS4 fût Model "Fût" is designed for drums and tanks of height less than 1000 mm. There is no guiding tube for the float; fitting is threaded. Reading tube comes with a graduated scale (one mark each 1 cm).
Each indicator is designed according the density of the liquid and height to monitor. Note: liquid surface is at 70 to 80% of float height.
Option: Level switches The pointer with a built-in magnet allows actuation of level switches BSM 501 or BRK60/32 (data-sheets 585-01 & -02).
General Catalog 584-01 14/11/2018 16:30
Tank top level indicator FS4
BAMO Mesures SAS
22, Rue de la Voie des Bans Parc d'activités de la Gare
95100 ARGENTEUIL France